BASIC CABLE INFORMATION:
APPLICATION:
Elevator suspension cable for indoor and panoramic elevators.
INSTALLATION:
To comply with the correct installation procedures please refer to the Changshun Product Catalog which is available separately.
THE COMPOSITION STRUCTURE AND SPECIFIC INFORMATION OF CABLE ARE AS FOLLOWS:
|
Component Core Wire | |
2 Twisted Pair/20AWG |
5/20AWG |
1/18AWG |
4/14AWG |
|
Conductor Material | |
TR Soft Copper Wire |
TR Soft Copper Wire |
TR Soft Copper Wire |
TR Soft Copper Wire |
|
|
Insulation Material |
PVC Class 4 |
PVC Class 4 |
PVC Class 4 |
PVC Class 4 |
|
THE CONDUCTOR NUMBERING ARE AS FOLLOWS:
|
Size |
Conductor Number And Color |
|
20AWG |
Red P28-2/ADS、Red P28-4/FDS |
|
|
18AWG |
Red P30-1/GTC-1 |
|
|
14AWG |
Orange P15-3/HL2、Light Purple P15-4/30DC4、Orange P10-2/HL2、Light Purple P10-1/RSL_30V |
|
|
Twisted Pair/20AWG |
Brown P15-1/HDL1 and Red P15-2/HDL2、Brown P10-4/GDL1 and Red P10-3/GDL2 |
|
THE MECHANICAL PROPERTIES:
|
Operating Temperature(℃): | |
60 |
|
Cable Net Weight Approx. (lbs/kft [kg/km]): | |
158.58[236.00] |
|
Overall Dimensios Approx. (W/H, in [mm]): | |
0.539[13.7] |
|
Copper Content.(lbs/kft [kg/km]): | |
97.76[145.50] |
|
Flame property: | |
FT1 |
THE ELECTRICAL PROPERICAL:
|
Maximum Voltage: | |
300V |
|
The conductor resistance of the 14 AWG(Ω/km): | |
≤8.88 |
|
The conductor resistance of the 18 AWG(Ω/km): | |
≤22.4 |
|
The conductor resistance of the 20 AWG(Ω/km): | |
≤35.7 |
CERTIFICATION & STANDARDS:
|
Certification: |
 |
|
CSA File Number: |
253817 |
|
CSA Standard: |
CSA C22.2 No.49 |
|
UL Standard: |
UL 758、UL1581 |