BASIC CABLE INFORMATION:

APPLICATION:

Elevator suspension cable for indoor and panoramic elevators.

INSTALLATION:

To comply with the correct installation procedures please refer to the Changshun Product Catalog which is available separately,for the DLB6367 cable ,secure it with the PX025003 nylon cable clamp during mounting.

THE COMPOSITION STRUCTURE AND SPECIFIC INFORMATION OF CABLE ARE AS FOLLOWS:

Component Core Wire 2/14AWG 2 Shielded      Pairs /20 AWG 24/18AWG
Material
Conductor  Material TR Soft Copper Wire TR Soft Copper Wire TR Soft Copper Wire
Insulation   Material PVC Class 4 PVC Class 4 PVC Class 4
Shielded     Material Aluminum Foil
Inner Sheath Material PVC Class 1.5
Outer Sheath Material PVC Class 1.5

THE CONDUCTOR NUMBERING ARE AS FOLLOWS:

Size Conductor Number And Color
14AWG Green 003、Purple 004
18AWG Yellow 001 to 010
Orange 011 to 020
TAN 021 to 024
Shielded Pair /20 AWG Red/White pair

THE MECHANICAL PROPERTIES:

Maximum Freely Suspended Length(ft[mm]): 200[61]
Maximum Travelling Height(ft[mm]): 400[122]
Maximun Running Speed(m/s): 10
Acceleration:
Operating Temperature(℃): -20 to +60
Recommended Loop Diameter(mm): 392[±100]
Cable Net Weight Approx. (lbs/ft [kg/m]): 0.6[0.9]
Overall Dimensios Approx. (W/H, in [mm]): 2.04 / 0.39[51.8 / 9.8]
Copper Content.(lbs/kft [kg/km]): 174.22[240.92]
Flame property: FT1

THE ELECTRICAL PROPERICAL:

Maximum Voltage: 300V
Twisted Pair Attenuation Characteristics.(dB/100m):
Coaxial Cable Attenuation Characteristics.(dB/100m):
Fiber Optic Cable Attenuation Characteristics.(dB/100m):
Coaxial Cable Transfer Impedance.(Ω/km):
The conductor resistance of the 14 AWG(Ω/km): ≤8.88
The conductor resistance of the 18 AWG(Ω/km): ≤22.4
The conductor resistance of the 20 AWG(Ω/km): ≤35.7

CERTIFICATION & STANDARDS:

Certification:      
CSA File Number: 253817
CSA Standard: CSA C22.2 No.49
UL Standard: UL 62